RMG
RMG series includes radar level transmitters. The level of liquids is measured by transmitting low energy radar pulses towards the liquid surface and receiving the radar echoes. The travel time for the radar pulse is proportional to the distance between the gauge and the surface. The radar pulse is unaffected by the tank content and atmosphere, temperature or pressure.
TS02
The efforts of Valcom® in researching and developing
innovative solutions for level measurement have succeeded
in realising the Tank Sonarâ TS02 sensor (International
Patent pending). Acoustic waves guided into a Æ 28 mm
(typical) pipe installed inside the tank permit to measure the
liquid level with a very high accuracy.
TLM
TLM (Tank Level Monitor) is a simple to operate graphical
display and data logger software running in the windows
environment, which provides the user with a clear picture of
the
current values of parameters such as level, pressure,
temperature and mass related to any storage tank provided with
Valcom® Tank Sonar system. Displays are arranged in a
number of windows according to the number of tank connected
to the same acquisition unit (TS02 controller). Tank Level
Monitor also provides logging functions and alarm reporting.
T7K series includes differential pressure electronic transmitters with capacitive cell featured by all AISI316L St.St. execution and 340° rotating head. Electronics is available in the following executions: Smart with 4-20mA and HART® protocol output, complete with digital display and push buttons for local configuration or without digital display and push buttons (remote configuration through HART® communicators).
T7T
T7T series includes SMART temperature electronic transmitters with 4÷20 mA output and HART® digital communication protocol able to accept Pt 100 ohm 3 wires resistance thermometers. The transmitter is ATEX certified and can be directly mounted in hazardous areas. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators
T7MPX
T7-MPX is an electronic temperature transmitter for connection
to Pt
100 resistance thermometers. It features a built-in multiplexer
and can
accept up to 15 resistance thermometers (3-wires). Instrument is
Ex ia
certified and can be directly mounted in hazardous areas; it offers
great
advantages for his mounting simplicity and for saving connection
cables. Output is analog 4÷20mA for averaging temperature
measurement only or Hart® protocol for single points values
or
average. Easy and simple installation saves cables and money.
Accuracy is depending on class of the sensors utilized such as
DIN A,
DIN B, 1/4 DIN, 1/10 DIN, etc.
T7B Working system of T7BL (level) and T7BD (density) series
transmitters is based on Archimede’s buoyancy principle.
These instruments are designed for continuous measurement
of level, interface and density of liquids in all industrial
applications, offering very high reliability and robustness within
a wide pressure and temperature range:
-1÷100 bar / -200°C ÷ +250°C.
T7SG
T7SG series includes transmitters for continuous specific gravity
measurement in liquid, mud, cement slurry, etc, manufactured
using
two seals placed at a fixed distance and connected through capillaries
to a DP cell. The instrument gives the specific gravity value
of
the product by measuring the hydrostatic pressure between the two
seals (Dp) and applying the formula SG=Dp/d where “SG” is
the specific gravity, “Dp” is the differential
pressure and “d” is the distance between the two
seals. T7SG series transmitters are manufactured with an especially
heavy duty mechanical construction and allows signal output
both in analogical 4÷20 mA and digital HART® protocol
form. T7SG series transmitters are used in all industry branches
for continuous specific gravity measurement of liquids in tanks.
T7D
T7D series includes differential pressure SMART electronic transmitters
with 4÷20 mA output and HART® digital communication
protocol. Configurations and adjustments can be made locally
by means of push buttons and display or remotely using HART® protocol
compatible communicators. T7D Series transmitters are used
in industrial applications to measure absolute relative or
differential pressures of liquids, gas and vapours, to measure
relative or differential level of liquids and to measure the
flow rate (output can be linear or proportional to the v?p
value). Instrument’s body is designed to sustain static
pressures up to 75 bar.
T7L
T7LG series includes Float Reed level transmitters. Inside the
float is placed a toroidal magnet which drives, without contact,
Reed contacts located inside the guide pipe. Moving along the
guide pipe the float changes the reed contact status. These
variations are then acquired by the electronic board and
converted both into an analog 4÷20 mA current and digital
HART® protocol signals. This system allows a continuous level
measurement with high repeatability.
Reed chain replacement can be done without dismantling the
transmitter from the process and doesn’t need any recalibration.
27L 27LG series includes Float Reed level transmitters. Inside
the float
is placed a toroidal magnet which drives, without contact, Reed
contacts located inside the guide pipe. Moving along the guide
pipe
the float changes the reed contact status. These variations are
then
acquired by the electronic board and converted into a current
signal.
This system enable a continuous level measurement (output 4÷20
mA) with high repeatability and linear level indication independently
from tank shap, or allows to realize on-off controls by using
two
floats (output On-Off 5÷15 mA). Reed chain replacement
can be
done without dismantling the transmitter from the process and
doesn’t need any recalibration.
T79
T79 series includes electronic transmitters featured by all AISI316L
St.St. execution, and housing available with direct bottom or back
process connections.
Electronics is available in the following executions:
a) Smart type with 4-20mA + HART® protocol output, complete
with digital display and push buttons for local configuration.
b) Smart type with 4-20mA + HART® protocol output, without
digital display and push buttons (remote configuration through
HART® communicators)
c) Smart type with 4-20 mA analogue output only, without digital
display; data acquisition by means of push buttons.
T7IM
T79-IM series includes SMART electronic transmitters with 4÷20
mA output and HART® digital communication protocol available
with piezoresistive (P series) or Ceramic (C series) sensor.
Piezoresistive sensor are based on silicon chip resistive
Wheatstone bridge while ceramic sensors are thick film sensors
based on strain gauge principle with backplate and diaphragm in
ceramic material; in both versions the sensors are calibrated
individually together with their own seal. Configurations and
adjustments can be made locally, by means of push buttons and
display, or remotely using HART® communication protocol.
T7N
T7N series includes SMART electronic transmitters with 4÷20
mA output and HART® digital communication protocol available
with piezoresistive (P series) or Ceramic (C series) sensor. In
both versions the sensors are calibrated individually together
with their own seal. Configurations and adjustments can be made
locally by means of push buttons and display or remotely using
HART® protocol compatible communicators. T7N Series transmitters
are used in industrial applications to detect pressure and level
of liquids, gas and vapours. Our technical office is at your disposal
for special applications.
27S 27S series allows the measurement of pressure, vacuum
and level
of liquids, in industrial process at different working conditions.
These
transmitters have a Smart-Hart® type electronic provided
with
programmable threshold and a microcontroller, which allows a
more
accurate and reliable management of the sensor if compared with
the traditional analogue transmitters, also giving diagnostic
information about the transmitter functioning.
OMDS
OMDS is an atmospheric oil mist detection system for marine applications, developed for installation in machinery room, pump room, etc. in commercial, naval, ro-ro ships as requested by the actual international IMO marine regulations (circ. 1086). The OMD detector is an independent measuring and transmitting system with 4÷20mA+HART® output, proportional to the density of oil mist in the sampled air; the instrument is engineered for connection to alarm acquisition Valcom® OMD panel.
ASL400
ASL400 is designed for marine and on-land applications for liquid
detection, pump control, water ingress alarm systems, for high
and
low alarm level, overfilling protection on liquids with or without
foam. ASL400 works on the principle of distributed acoustic
waves
in a metal rod. If the rod is not covered by the liquid the sound
waves are dispersed freely without any interference. If liquid
covers
the rod the emission of sound waves is muffled and this interference
is picked up by the piezoelectric sensor and converted into
a current
signal in the current loop (on-off). These instruments have no
moving parts, no vibration, no optical or capacitive detectors.
They are
pure static sensors offering the maximum reliability.
LSG
LSG is a float level switch designed for liquid level control
in marine and
industrial fields.
Typical applications are high and overfilling protection, water
presence
detection, high and low alarm level of liquids with or without
foam.
Inside the float is placed a toroidal magnet which drives, without
contact, a
switch located inside the guide pipe; instrument have to be supplied
with a
constant voltage of 24Vdc (for example by means of TSU400FM barrier)
in
order to provide two constant current output values related to
alarm
thresholds (On=5mA / Off=13mA). Switch replacement can be done
without dismantling instrument from the process and doesn’t
need any
recalibration.
TSU400
The galvanically isolated safety barriers TSU400 are valid alternative
to passive barriers because they don’t need a high integrity
I.S. ground, being the isolation between the safe area and
the hazardous area guaranteed by a transformer. TSU400 series
barriers have an intrinsic voltage regulation of the supply
and are designed for connection to ON-OFF sensors having a
mA output so that they permit to interface 5/13 mA two wire
switching instruments also giving a relay output. They are
especially suitable for ships applications and for hazardous
areas installations being certified [EEx ia] IIC. Great advantages
are offered by the use of TSU400 series barriers interfaced
with Valcom® ultrasonic level switches ASL400 series.
A2X
The process indicators A2X series are configurable microprocessor
devices, with analog input selectable via terminal block connection
for measurements in mA or V DC Maximum display scale ± 99999
with programmable reading scale and decimal point by means
of four keys keypad and seven-segment display (character height
12.5 mm). Start and end of scale calibration in self-learning
mode through two external digital inputs and Loop interruption
monitoring with visual indicator and output override (for 4...20
mA signals) are only some of its features.