Chemical
Marine
Food
Paper
Liquefied Petroleum Gas - Products
30 years of innovation, quality and service on demand.
 
 


RMG
RMG series includes radar level transmitters. The level of liquids is measured by transmitting low energy radar pulses towards the liquid surface and receiving the radar echoes. The travel time for the radar pulse is proportional to the distance between the gauge and the surface. The radar pulse is unaffected by the tank content and atmosphere, temperature or pressure.

> Datasheet (pdf, 430Kb)

 


TS02
The efforts of Valcom® in researching and developing innovative solutions for level measurement have succeeded in realising the Tank Sonarâ TS02 sensor (International Patent pending). Acoustic waves guided into a Æ 28 mm (typical) pipe installed inside the tank permit to measure the liquid level with a very high accuracy.

> Datasheet (pdf, 1.024Kb)

 

TLM
TLM (Tank Level Monitor) is a simple to operate graphical display and data logger software running in the windows environment, which provides the user with a clear picture of the current values of parameters such as level, pressure, temperature and mass related to any storage tank provided with Valcom® Tank Sonar system. Displays are arranged in a number of windows according to the number of tank connected to the same acquisition unit (TS02 controller). Tank Level Monitor also provides logging functions and alarm reporting.


> Datasheet (pdf, 1000Mb)

 


T7K

T7K series includes differential pressure electronic transmitters with capacitive cell featured by all AISI316L St.St. execution and 340° rotating head. Electronics is available in the following executions: Smart with 4-20mA and HART® protocol output, complete with digital display and push buttons for local configuration or without digital display and push buttons (remote configuration through HART® communicators).



>Datasheet (pdf, 274Kb)

 


T7T
T7T series includes SMART temperature electronic transmitters with 4÷20 mA output and HART® digital communication protocol able to accept Pt 100 ohm 3 wires resistance thermometers.  The transmitter is ATEX certified and can be directly mounted in hazardous areas. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators

> Datasheet (pdf, 400Kb)

 


T7MPX
T7-MPX is an electronic temperature transmitter for connection to Pt 100 resistance thermometers. It features a built-in multiplexer and can accept up to 15 resistance thermometers (3-wires). Instrument is Ex ia certified and can be directly mounted in hazardous areas; it offers great advantages for his mounting simplicity and for saving connection cables. Output is analog 4÷20mA for averaging temperature measurement only or Hart® protocol for single points values or average. Easy and simple installation saves cables and money.
Accuracy is depending on class of the sensors utilized such as DIN A, DIN B, 1/4 DIN, 1/10 DIN, etc.

> Datasheet (pdf, 600Kb)

 


T7B
Working system of T7BL (level) and T7BD (density) series transmitters is based on Archimede’s buoyancy principle.
These instruments are designed for continuous measurement of level, interface and density of liquids in all industrial applications, offering very high reliability and robustness within a wide pressure and temperature range:
-1÷100 bar / -200°C ÷ +250°C.

> Datasheet (pdf, 581Kb)

 


T7SG
T7SG series includes transmitters for continuous specific gravity measurement in liquid, mud, cement slurry, etc, manufactured using two seals placed at a fixed distance and connected through capillaries to a DP cell. The instrument gives the specific gravity value of the product by measuring the hydrostatic pressure between the two seals (Dp) and applying the formula SG=Dp/d where “SG” is the specific gravity, “Dp” is the differential pressure and “d” is the distance between the two seals. T7SG series transmitters are manufactured with an especially heavy duty mechanical construction and allows signal output both in analogical 4÷20 mA and digital HART® protocol form. T7SG series transmitters are used in all industry branches for continuous specific gravity measurement of liquids in tanks.

> Datasheet (pdf, 1Mb)

 


T7D
T7D series includes differential pressure SMART electronic transmitters with 4÷20 mA output and HART® digital communication protocol. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators. T7D Series transmitters are used in industrial applications to measure absolute relative or differential pressures of liquids, gas and vapours, to measure relative or differential level of liquids and to measure the flow rate (output can be linear or proportional to the v?p value). Instrument’s body is designed to sustain static pressures up to 75 bar.

> Datasheet (pdf, 400Kb)

 

T7L
T7LG series includes Float Reed level transmitters. Inside the float is placed a toroidal magnet which drives, without contact, Reed contacts located inside the guide pipe. Moving along the guide pipe the float changes the reed contact status. These variations are then acquired by the electronic board and converted both into an analog 4÷20 mA current and digital HART® protocol signals. This system allows a continuous level
measurement with high repeatability.
Reed chain replacement can be done without dismantling the transmitter from the process and doesn’t need any recalibration.

> Datasheet (pdf, 1Mb)

 

27L
27LG series includes Float Reed level transmitters. Inside the float is placed a toroidal magnet which drives, without contact, Reed contacts located inside the guide pipe. Moving along the guide pipe the float changes the reed contact status. These variations are then acquired by the electronic board and converted into a current signal.
This system enable a continuous level measurement (output 4÷20 mA) with high repeatability and linear level indication independently from tank shap, or allows to realize on-off controls by using two floats (output On-Off 5÷15 mA). Reed chain replacement can be done without dismantling the transmitter from the process and doesn’t need any recalibration.

> Datasheet (pdf, 514Kb)

 

T79
T79 series includes electronic transmitters featured by all AISI316L St.St. execution, and housing available with direct bottom or back process connections.
Electronics is available in the following executions:
a) Smart type with 4-20mA + HART® protocol output, complete
with digital display and push buttons for local configuration.
b) Smart type with 4-20mA + HART® protocol output, without
digital display and push buttons (remote configuration through
HART® communicators)
c) Smart type with 4-20 mA analogue output only, without digital
display; data acquisition by means of push buttons.

> Datasheet (pdf, 481Kb)

 

T7IM
T79-IM series includes SMART electronic transmitters with 4÷20
mA output and HART® digital communication protocol available with piezoresistive (P series) or Ceramic (C series) sensor.
Piezoresistive sensor are based on silicon chip resistive Wheatstone bridge while ceramic sensors are thick film sensors
based on strain gauge principle with backplate and diaphragm in
ceramic material; in both versions the sensors are calibrated individually together with their own seal. Configurations and adjustments can be made locally, by means of push buttons and
display, or remotely using HART® communication protocol.

> Datasheet (pdf, 897Kb)

 


T7N
T7N series includes SMART electronic transmitters with 4÷20 mA output and HART® digital communication protocol available with piezoresistive (P series) or Ceramic (C series) sensor. In both versions the sensors are calibrated individually together with their own seal. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators. T7N Series transmitters are used in industrial applications to detect pressure and level of liquids, gas and vapours. Our technical office is at your disposal for special applications.

> Datasheet (pdf, 883Kb)

 


27S
27S series allows the measurement of pressure, vacuum and level of liquids, in industrial process at different working conditions. These transmitters have a Smart-Hart® type electronic provided with programmable threshold and a microcontroller, which allows a more accurate and reliable management of the sensor if compared with the traditional analogue transmitters, also giving diagnostic information about the transmitter functioning.

> Datasheet (pdf, 600Kb)

 


OMDS
OMDS is an atmospheric oil mist detection system for marine applications, developed for installation in machinery room, pump room, etc. in commercial, naval, ro-ro ships as requested by the actual international IMO marine regulations (circ. 1086). The OMD detector is an independent measuring and transmitting system with 4÷20mA+HART® output, proportional to the density of oil mist in the sampled air; the instrument is engineered for connection to alarm acquisition Valcom® OMD panel.

> Datasheet (pdf, 600kb)

 


ASL400
ASL400 is designed for marine and on-land applications for liquid detection, pump control, water ingress alarm systems, for high and low alarm level, overfilling protection on liquids with or without foam. ASL400 works on the principle of distributed acoustic waves in a metal rod. If the rod is not covered by the liquid the sound waves are dispersed freely without any interference. If liquid covers the rod the emission of sound waves is muffled and this interference is picked up by the piezoelectric sensor and converted into a current signal in the current loop (on-off). These instruments have no moving parts, no vibration, no optical or capacitive detectors. They are pure static sensors offering the maximum reliability.

> Datasheet (pdf, 880Kb)

 

LSG
LSG is a float level switch designed for liquid level control in marine and industrial fields.
Typical applications are high and overfilling protection, water presence detection, high and low alarm level of liquids with or without foam.
Inside the float is placed a toroidal magnet which drives, without contact, a switch located inside the guide pipe; instrument have to be supplied with a constant voltage of 24Vdc (for example by means of TSU400FM barrier) in order to provide two constant current output values related to alarm thresholds (On=5mA / Off=13mA). Switch replacement can be done without dismantling instrument from the process and doesn’t need any
recalibration.

> Datasheet (pdf, 390Kb)

 


TSU400
The galvanically isolated safety barriers TSU400 are valid alternative to passive barriers because they don’t need a high integrity I.S. ground, being the isolation between the safe area and the hazardous area guaranteed by a transformer. TSU400 series barriers have an intrinsic voltage regulation of the supply and are designed for connection to ON-OFF sensors having a mA output so that they permit to interface 5/13 mA two wire switching instruments also giving a relay output. They are especially suitable for ships applications and for hazardous areas installations being certified [EEx ia] IIC. Great advantages are offered by the use of TSU400 series barriers interfaced with Valcom® ultrasonic level switches ASL400 series.

> Datasheet (pdf, 716Kb)

 


A2X
The process indicators A2X series are configurable microprocessor devices, with analog input selectable via terminal block connection for measurements in mA or V DC Maximum display scale ± 99999 with programmable reading scale and decimal point by means of four keys keypad and seven-segment display (character height 12.5 mm). Start and end of scale calibration in self-learning mode through two external digital inputs and Loop interruption monitoring with visual indicator and output override (for 4...20 mA signals) are only some of its features.

> Datasheet (pdf, 199Kb)



Oil & Gas


Products:
RMG
TS02
TLM
T7K
T7T
T7MPX
T7B
T7SG
T7D
T7L
27L
T79
T7IM
T7N
27S
OMDS
ASL400
LSG
TSU400
A2X
©2006 Copyright © Valcom. All rights reserved. Terms of use & Privacy policy.
For any question contact webmaster