Chemical
Marine
Food
Paper
Marine - Products
30 years of innovation, quality and service on demand.  
 
 


27
27 series includes electronic pressure transmitters available with piezoresistive (P series) or Ceramic (C series) sensor. All 27 series versions has small sizes (typical housing Ø27 mm) and fixed ranges (when possible to adjust zero and span, this can be done within ± 10%). 27 Series transmitters are used in industrial and marine applications detect pressure of liquids, gas and vapours.

> Datasheet (pdf, 782Kb)

 


27IM
27IM series includes submersible electronic level transmitters for hydrostatic pressure sensing, available with piezoresistive (P series) or ceramic (C series) sensor. All 27IM series versions has small sizes (housing ØMax 35 mm) and fixed ranges. 27IM Series transmitters are used in industrial and marine applications to measure level of liquids in wells, chests, lakes, water treatment plants, tanks, etc.

> Datasheet (pdf, 514Kb)
 


27S
27S series allows the measurement of pressure, vacuum and level of liquids, in industrial process at different working conditions. These transmitters have a Smart-Hart® type electronic provided with programmable threshold and a microcontroller, which allows a more accurate and reliable management of the sensor if compared with the traditional analogue transmitters, also giving diagnostic information about the transmitter functioning.

> Datasheet (pdf, 600Kb)

 


T7N
T7N series includes SMART electronic transmitters with 4÷20 mA output and HART® digital communication protocol available with piezoresistive (P series) or Ceramic (C series) sensor. In both versions the sensors are calibrated individually together with their own seal. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators. T7N Series transmitters are used in industrial applications to detect pressure and level of liquids, gas and vapours. Our technical office is at your disposal for special applications.

> Datasheet (pdf, 883Kb)

 


T7D
T7D series includes differential pressure SMART electronic transmitters with 4÷20 mA output and HART® digital communication protocol. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators. T7D Series transmitters are used in industrial applications to measure absolute relative or differential pressures of liquids, gas and vapours, to measure relative or differential level of liquids and to measure the flow rate (output can be linear or proportional to the v?p value). Instrument’s body is designed to sustain static pressures up to 75 bar.

> Datasheet (pdf, 400Kb)

 


T7K

T7K series includes differential pressure electronic transmitters with capacitive cell featured by all AISI316L St.St. execution and 340° rotating head. Electronics is available in the following executions: Smart with 4-20mA and HART® protocol output, complete with digital display and push buttons for local configuration or without digital display and push buttons (remote configuration through HART® communicators).



>Datasheet (pdf, 274Kb)

 


T7T
T7T series includes SMART temperature electronic transmitters with 4÷20 mA output and HART® digital communication protocol able to accept Pt 100 ohm 3 wires resistance thermometers.  The transmitter is ATEX certified and can be directly mounted in hazardous areas. Configurations and adjustments can be made locally by means of push buttons and display or remotely using HART® protocol compatible communicators

> Datasheet (pdf, 400Kb)

 

T79
T79 series includes electronic transmitters featured by all AISI316L St.St. execution, and housing available with direct bottom or back process connections.
Electronics is available in the following executions:
a) Smart type with 4-20mA + HART® protocol output, complete
with digital display and push buttons for local configuration.
b) Smart type with 4-20mA + HART® protocol output, without
digital display and push buttons (remote configuration through
HART® communicators)
c) Smart type with 4-20 mA analogue output only, without digital
display; data acquisition by means of push buttons.

> Datasheet (pdf, 481Kb)

 

T7IM
T79-IM series includes SMART electronic transmitters with 4÷20
mA output and HART® digital communication protocol available with piezoresistive (P series) or Ceramic (C series) sensor.
Piezoresistive sensor are based on silicon chip resistive Wheatstone bridge while ceramic sensors are thick film sensors
based on strain gauge principle with backplate and diaphragm in
ceramic material; in both versions the sensors are calibrated individually together with their own seal. Configurations and adjustments can be made locally, by means of push buttons and
display, or remotely using HART® communication protocol.

> Datasheet (pdf, 897Kb)

 

T7L
T7LG series includes Float Reed level transmitters. Inside the float is placed a toroidal magnet which drives, without contact, Reed contacts located inside the guide pipe. Moving along the guide pipe the float changes the reed contact status. These variations are then acquired by the electronic board and converted both into an analog 4÷20 mA current and digital HART® protocol signals. This system allows a continuous level
measurement with high repeatability.
Reed chain replacement can be done without dismantling the transmitter from the process and doesn’t need any recalibration.

> Datasheet (pdf, 1Mb)

 

27L
27LG series includes Float Reed level transmitters. Inside the float is placed a toroidal magnet which drives, without contact, Reed contacts located inside the guide pipe. Moving along the guide pipe the float changes the reed contact status. These variations are then acquired by the electronic board and converted into a current signal.
This system enable a continuous level measurement (output 4÷20 mA) with high repeatability and linear level indication independently from tank shap, or allows to realize on-off controls by using two floats (output On-Off 5÷15 mA). Reed chain replacement can be done without dismantling the transmitter from the process and doesn’t need any recalibration.

> Datasheet (pdf, 514Kb)

 


RMG
RMG series includes radar level transmitters. The level of liquids is measured by transmitting low energy radar pulses towards the liquid surface and receiving the radar echoes. The travel time for the radar pulse is proportional to the distance between the gauge and the surface. The radar pulse is unaffected by the tank content and atmosphere, temperature or pressure.

> Datasheet (pdf, 430Kb)

 


TS02
The efforts of Valcom® in researching and developing innovative solutions for level measurement have succeeded in realising the Tank Sonarâ TS02 sensor (International Patent pending). Acoustic waves guided into a Æ 28 mm (typical) pipe installed inside the tank permit to measure the liquid level with a very high accuracy.

> Datasheet (pdf, 1.024Kb)

 


T7MPX
T7-MPX is an electronic temperature transmitter for connection to Pt 100 resistance thermometers. It features a built-in multiplexer and can accept up to 15 resistance thermometers (3-wires). Instrument is Ex ia certified and can be directly mounted in hazardous areas; it offers great advantages for his mounting simplicity and for saving connection cables. Output is analog 4÷20mA for averaging temperature measurement only or Hart® protocol for single points values or average. Easy and simple installation saves cables and money.
Accuracy is depending on class of the sensors utilized such as DIN A, DIN B, 1/4 DIN, 1/10 DIN, etc.

> Datasheet (pdf, 600Kb)

 


T7SG
T7SG series includes transmitters for continuous specific gravity measurement in liquid, mud, cement slurry, etc, manufactured using two seals placed at a fixed distance and connected through capillaries to a DP cell. The instrument gives the specific gravity value of the product by measuring the hydrostatic pressure between the two seals (Dp) and applying the formula SG=Dp/d where “SG” is the specific gravity, “Dp” is the differential pressure and “d” is the distance between the two seals. T7SG series transmitters are manufactured with an especially heavy duty mechanical construction and allows signal output both in analogical 4÷20 mA and digital HART® protocol form. T7SG series transmitters are used in all industry branches for continuous specific gravity measurement of liquids in tanks.

> Datasheet (pdf, 1Mb)

 


ASL400
ASL400 is designed for marine and on-land applications for liquid detection, pump control, water ingress alarm systems, for high and low alarm level, overfilling protection on liquids with or without foam. ASL400 works on the principle of distributed acoustic waves in a metal rod. If the rod is not covered by the liquid the sound waves are dispersed freely without any interference. If liquid covers the rod the emission of sound waves is muffled and this interference is picked up by the piezoelectric sensor and converted into a current signal in the current loop (on-off). These instruments have no moving parts, no vibration, no optical or capacitive detectors. They are pure static sensors offering the maximum reliability.

> Datasheet (pdf, 880Kb)

 

LSG
LSG is a float level switch designed for liquid level control in marine and industrial fields.
Typical applications are high and overfilling protection, water presence detection, high and low alarm level of liquids with or without foam.
Inside the float is placed a toroidal magnet which drives, without contact, a switch located inside the guide pipe; instrument have to be supplied with a constant voltage of 24Vdc (for example by means of TSU400FM barrier) in order to provide two constant current output values related to alarm thresholds (On=5mA / Off=13mA). Switch replacement can be done without dismantling instrument from the process and doesn’t need any
recalibration.

> Datasheet (pdf, 390Kb)

 


TSU400
The galvanically isolated safety barriers TSU400 are valid alternative to passive barriers because they don’t need a high integrity I.S. ground, being the isolation between the safe area and the hazardous area guaranteed by a transformer. TSU400 series barriers have an intrinsic voltage regulation of the supply and are designed for connection to ON-OFF sensors having a mA output so that they permit to interface 5/13 mA two wire switching instruments also giving a relay output. They are especially suitable for ships applications and for hazardous areas installations being certified [EEx ia] IIC. Great advantages are offered by the use of TSU400 series barriers interfaced with Valcom® ultrasonic level switches ASL400 series.

> Datasheet (pdf, 716Kb)

 


BMS
BMS is a bubbling system for level detection based on the
measurement of hydrostatic pressure caused by the liquid contained in the tank. The working principle is founded on the measure of the pressure value needed to maintain a constant and regular air flow through a pipe probe open in the bottom and submerged into the liquid. At any level variation of the liquid in the tank corresponds a variation of the hydrostatic pressure applied on the air outgoing from the probe pipe; these pressure variations are precisely detected by the 27M P/I converter and converted into a standard 4÷20 mA electric signal. PR3 regulator keeps constant bubbling air flow at any level value, assuring high precision measurement.

> Datasheet (pdf, 200Kb)

 


OMDS
OMDS is an atmospheric oil mist detection system for marine applications, developed for installation in machinery room, pump room, etc. in commercial, naval, ro-ro ships as requested by the actual international IMO marine regulations (circ. 1086). The OMD detector is an independent measuring and transmitting system with 4÷20mA+HART® output, proportional to the density of oil mist in the sampled air; the instrument is engineered for connection to alarm acquisition Valcom® OMD panel.

> Datasheet (pdf, 600kb)

 


WISE
WISE is a system for water ingress detection designed in accordance to SOLAS XII/12 requirements and MSC 145 (77) resolution for applications on bulk carriers. The system is composed by the following main components:

  • Static level switch ASL400 series with a complete St.St. AISI 316 construction, including cable gland.;
  • 2 channel galvanically isolated safety barrier TSU400 series with intrinsic voltage regulation of the supply;
  • Control panel complete with indication lights and buzzer for visual and acoustic signals (ISA sequence) of the pre-alarm, alarm , fault (short circuit, cable interruption or low insulation) and power failure conditions (main and auxiliary).
 


STHOP
STHOP is a high (95%) and overfill (98%) alarm system for installation on tank ships, designed in accordance to classification societies requirements, to IMO A686 resolution and to USCG 46 CFR PART 39-20.7 rules. The system is composed by the following main components:

  • Static level switch ASL400 series with a complete St.St. AISI 316 construction, including cable gland.
  • 2 channels galvanically isolated safety barrier TSU400 series with intrinsic supply voltage regulation;
  • Control panel complete with indication lights and buzzers for visual and acoustic signals (ISA sequence) of the high (95%) and overfill (98%) alarm, fault (short circuit, cable interruption) and power failure conditions (main and
    auxiliary).
 


ASAP1-2
ASAP1-2 is a system for the monitoring measuring and control of variables on ships, in accordance to all requirements and resolutions. The system can acquire signals from pressure, level and temperature transmitters. The flexibility of programming allows various kinds of applications.

 


ASAP3
ASAP3 is a permanent system designed to meet the requirements of IMO/SOLAS and Classification rules, for monitoring toxic gas and oxygen in pump room. In its standard configuration the system is consisting of:
- Alarm panel with 2 sensors per module;
- Gas sensor (Hydrogen Sulphide or Oxygen);
- Power failure relay output;
- Common alarm relay output for each gas type.

> Datasheet (pdf, 1000Kb)

 


AUT-BGD
Valcom® AUTomatic Ballast Gas Detection system (AUT-BGD) is a fully computerized gas sampling system for gases such as  Hexane, Isobutane, Methane, Propane. The system fulfills latest requirements from IACS, EC, IMO and all major classification societies, rules and regulations.

> Datasheet (pdf, 243Kb)



Oil & Gas


Products:
27
27IM
27S
T7N
T7D
T7K
T7T
T79
T7IM
T7L
27L
RMG
TS02
T7MPX
T7SG
ASL400
LSG
TSU400
BMS
OMDS

WISE

STHOP

ASAP1-2
ASAP3
AUT-BGD
©2006 Copyright © Valcom. All rights reserved. Terms of use & Privacy policy.